Configuring Readers
78 Level 2 API
/reader/radio/powerMax
Type: integer
Writable: no
Products: all
Maximum value that the reader accepts for transmit power.
/reader/radio/powerMin
Type: integer
Writable: no
Products: all
Minimum value that the reader accepts for transmit power.
/reader/radio/portReadPowerList
Type: array of array of integers
Default value: From reader
Writable: yes
Products: M5e (and derived products), M6e, M6
List of per-port transmit power values for read operations. Each list element is a length-
two array. The first element is the port number, and the second element is the power level
in centidBm. Ports not listed are assigned a per-port power level of 0 (which indicates it
will use the global read power level:
/reader/radio/readPower)
/reader/radio/portWritePowerList
Type: array of array of integers
Default value: From reader
Writable: yes
Products: M5e (and derived products), M6e, M6
List of per-port transmit power values for write operations. Each list element is a length-
two array. The first element is the port number, and the second element is the power level
in centidBm. Ports not listed are assigned a per-port power level of 0 (which indicates it
Vue de la page 77